A $60 \: \mathrm{cm}$ diameter well completely penetrates a confined aquifer of permeability $5 \times 10^{-4} \mathrm{~m} / \mathrm{s}$. The length of the strainer (spanning the entire thickness of the aquifer) is $10 \: \mathrm{m}$. The drawdown at the well under steady state pumping is $1.0 \: \mathrm{m}$. Assume that the radius of influence for this pumping is $300 \: \mathrm{m}$ .
The discharge from the well (in litres per minute) is $\_\_\_\_\_\_\_\_\_\_\_$ (round off to the nearest integer).